Specifications:
Operating voltage: DC 5-12V(5V 6V 9V 12V)
Operating current: 5V,forward 4ma, reverse: 36ma;12V, Forward 6ma, reverse: 44ma;
Load voltage: DC 1-48V OR AC 85-265V
Load current: Maximum 2A
Forward maximum time: 5000 seconds, 0.1 seconds step
Reverse maximum time: 5000 seconds, 0.1 seconds step
By "Time multiple selection" setting,The maximum delay of up to 40,000 seconds.(short-circuited pad)
Size: 54 x 22 x 15 mm
How to Use:
VIN connected to the positive of power supply , GND connected to the negative of power supply;
P+ connected to the positive of Motor power supply, P- connected to the negative of Motor power supply;
M + M- are connected to both ends of the motor
After power, D1 flashes 3 times, D2 off, M+ output positive, M- output negative, motor forward; after a time delay T1, D2 on, M+ output negative, M- output positive, motor reversal; after a time delay T2, D2 off, M+ output positive, M- output negativ, motor forward;and so on.
T1: indicates motor Forward delay time, default 0.1-5000 seconds adjustable (step 0.1 seconds)
T2: indicates motor Reverse delay time, default 0.1-5000 seconds adjustable (step 0.1 seconds)
By "Time multiple selection" setting,The maximum delay of up to 40,000 seconds
How to Set Up:
1. After power, D1 3 blinks, Enter the "work mode"
D2 on Reversal,D2 Off Forward
2. Press and hold the Key for 2 seconds,D1 on,enter the "setup mode"
D2 off, It's forward "setup mode"
3. In forward "setup mode", the continuous trigger KEY twice ,D1 off,entry "Standby timer mode"
4. In the "Standby timer mode" ,trigger KEY start timing(entry "Timing Mode")
D1 flashing said it is timing("Timing Mode")
Trigger KEY again to stop the clock(exit "Timing Mode")
D1 flashing time is forward time(T1)
5. Press and hold the Key for 2 seconds,D2 on,enter the Reverse "setup mode"
6. In Reverse "setup mode", the continuous trigger key twice ,D1 off,entry "Standby timer mode"
7. In the "Standby timer mode" ,trigger KEY start timing(entry "Timing Mode")
D1 flashing said it is timing("Timing Mode")
Trigger KEY again to stop the clock(exit "Timing Mode")
D1 flashing time is Reverse time(T2)
So far, forward time(T1) and reverse time(T2) is set up
Re-power in "work mode"
Package Included:
1 x CE032 DC 5V 6V 9V 12V Motor Reversible Controller
CE032 DC 5V 6V 9V 12V Motor Reversible Controller Time Adjustable Delay DPDT Relay Switch 2A 5000SSee detail