Friday, April 10, 2020

W3231 Incubator Temperature Controller Thermometer Cool/Heat Digital Dual Display with NTC Sensor AC 110-220V/DC12V/DC 24V

W3231 Incubator Temperature Controller Thermometer Cool/Heat Digital Dual Display with NTC Sensor AC 110-220V/DC12V/DC 24V
W3231 Incubator Temperature Controller Thermometer Cool/Heat Digital Dual Display with NTC Sensor AC 110-220V/DC12V/DC 24VW3231 Incubator Temperature Controller Thermometer Cool/Heat Digital Dual Display with NTC Sensor AC 110-220V/DC12V/DC 24VW3231 Incubator Temperature Controller Thermometer Cool/Heat Digital Dual Display with NTC Sensor AC 110-220V/DC12V/DC 24V



Description:

Temperature Control Range: -55°C~120°C/-67°F~ 248°F
Temperature Control Accuracy: 0.1 °C / 0.1 °F
Display Color: Red + Blue
Working Power Supply: DC12V /DC 24V /AC110V~220V
Temperature Sensor: 1M NTC 10K 
Product Size: 79.2mm×41.9mm×26.3mm
Hole Size: 72.1mm×39.2mm
 
Operation and Display Panel

Temperature Controller Panel

 

Warning code

 

Code

Reason for error

Solution

HHH

Temperature exceeds alarm temperature

The temperature drops below the alarm temperature and returns to normal.

LLL

No temperature sensor detected

Replacement reconnect temperature sensor

 

Indicator light

 

Color

Indicating situation

Red

The red light flashes and the heating mode is delayed.;The red light is always on, heating mode is running.

Blue

Blue light flashes, cooling mode delay starts;

The blue light is always on ,cooling mode is running.

 

Instructions:

1. Short press “SET” small dital tube to flash, press “△” or “▽” to set the target temperature, press “Standby” button or no operation to save the setting within 3 seconds.

2. Press and hold “SET” to enter the code setting mode, press “△” or “▽” to switch the code. After selecting, press “SET” to enter the code setting. After setting, press “Standby” button or no operation to save the setting within 3 seconds. .

3. The last parameter setting is saved by default after shutdown.

4, restore the factory settings: press and hold "SET" to power on.

5. When the module is powered on, it will start directly. After power-on, press and hold the “standby” button, the module will enter “sleep” or “wake up”;  if power failure, the module will run automatically after power recovery, no need to start manually.

 

Package Include:

 1 x W3231 Incubator Temperature Controller Thermometer





W3231 Incubator Temperature Controller Thermometer Cool/Heat Digital Dual Display with NTC Sensor AC 110-220V/DC12V/DC 24VBuy Now


Search This Blog

Follow Us @soratemplates